Parameter
Function
Unit
Default
value
Range Effective
Suitable
mode
Reference
chapter
P5-57.0~1
/PREFA: intenral position
selection signal A
-
00
0~ff
√
5
P5-57.2
SI terminal filtering time
ms
0
0~f
√
5
P5-58.0~1
/PREFB: intenral position
selection signal B
-
00
0~ff
√
5
P5-58.2
SI terminal filtering time
ms
0
0~f
√
5
P5-59.0~1
/PREFC: internal position
selection signal C
-
00
0~ff
√
5
P5-59.2
SI terminal filtering time
ms
0
f~f
√
5
P5-61.0~1
/TRAJ-START: Motion
start trigger signal
-
00
0~ff
√
5
P5-61.2
SI terminal filtering time
ms
0
0~f
√
5
P5-70
/SRDY: Output Conditions
Selection
0: This terminal is turned
on after initialization of the
driver is completed
1: This terminal will not
turn on until enabled.
-
0
0~1
√
1|2|3|4|5|6|7|
8|9|10
P5-71
Function Selection of
Directional Terminal of
Pulse Speed Mode
-
0
0~1
○
7
P6-XX
:
Parameter
Function
Unit
Default
value
Range Effective Suitable mode
Reference
chapter
P6-05
Adaptive Mode Speed Loop
Gain (Large Inertia)
0.1Hz
200
1~65535
○
1|2|3|4|5|6|7|8|9|
10
P6-07
Adaptive mode inertia ratio
(Large inertia)
%
50
0~10000
○
1|2|3|4|5|6|7|8|9|
10
P6-08
Gain of adaptive mode
speed observer (large
inertia)
Hz
40
10~1000
○
1|2|3|4|5|6|7|8|9|
10
P6-12
Maximum Inertia Ratio of
Adaptive Mode (Large
Inertia)
-
50
1~10000
○
1|2|3|4|5|6|7|8|9|
10
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......