P
t
After the drive output 1-segment position
command, it will not wait for the completion of
motor positioning, and start the next position
command at once.
P
t
t2
After the drive output 1-segment position
command, it will not wait for the completion of
motor positioning, but pass the adjust time, and
then start the next position command. T2 is adjust
time. Refer to parameter P4-11.
2. change step mode
n.xx□x
Description
0: Change
the step
when signal
is ON,
recycling
P
t
Segment 1
Segment 2
Segment 1
/CHGSTP
Signal status
t1
t2
t1
ON
OFF
t1=P4-16, t2=P4-23.
1. If the /CHGSTP signal is always on,
the servo unit will cycle the set position
segment all the time.
2. If the /CHGSTP signal is set to off
when executing a certain segment, the
servo will continue to complete the
execution of that segment without the
execution of the next segment.
3. In this mode, the step change signal
/CHGSTP is triggered at high level.
4. When the servo enable is off during a
certain section of operation, the motor
stops according to the servo off shutdown
mode. After the shutdown, the positioning
is invalid.
5. After each operation completion,
positioning completion and positioning
approach signal are all effective.
6. In this mode, the adjustment time of
each period is valid.
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......