Parameter
Function
Unit
Default
value
Range Effective
Suitable
mode
Reference
chapter
from SI2 terminal.
13: Inverse signal is input
from SI3 terminal.
14: Inverse signal is input
from SI4 terminal.
P5-20.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-21.0~1
/P-CON proportion action
instruction
-
00
0~ff
√
1|2|3|4|5|6|7|
8|9|10
P5-21.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-22.0~1
/P-OT: Forbidden forward
driving
-
03
0~ff
√
1|2|3|4|5|6|7|
8|9|10
5.2.4
P5-22.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-23.0~1
/N-OT: forbidden reverse
driving
-
04
0~ff
√
1|2|3|4|5|6|7|
8|9|10
5.2.4
P5-23.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-24.0~1
/ALM-RST: alarm clear
-
02
0~ff
√
1|2|3|4|5|6|7|
8|9|10
P5-24.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-25.0~1
/P-CL
:
External Torque
Limitation at Forward
Rotation Side
-
00
0~ff
√
1|2|3|4|5|6|7|
8|9|10
P5-25.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-26.0~1
/N-CL
:
External Torque
Limitation at Reverse
Rotation Side
-
00
0~ff
√
1|2|3|4|5|6|7|
8|9|10
P5-26.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-27.0~1
/SPD-D: Internal Speed
Direction Selection
-
00
0~ff
√
1|2|3|4|7
P5-27.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|7
P5-28.0~1
/SPD-A: Internal Setting
Speed Selection
-
00
0~ff
√
3|5
P5-28.2
SI terminal filtering time
ms
0
0~f
√
3|5
P5-29.0~1
/SPD-B: Internal Setting
Speed Selection
-
00
0~ff
√
3|5
P5-29.2
SI terminal filtering time
ms
0
0~f
√
3|5
P5-30.0~1
/C-SEL: control mode
selection
-
00
0~ff
√
1|2|3|4|5|6|7|
8|9|10
P5-30.2
SI terminal filtering time
ms
0
0~f
√
1|2|3|4|5|6|7|
8|9|10
P5-31.0~1
/ZCLAMP: zero position
clamping
-
00
0~ff
√
3|4|7
P5-31.2
SI terminal filtering time
ms
0
0~f
√
3|4|7
P5-32.0~1
/INHIBIT: Instruction
pulse prohibition
-
00
0~ff
√
5|6|7
5.3.1.4
P5-32.2
SI terminal filtering time
ms
0
0~f
√
5|6|7
P5-34.0~1
/CLR: pulse offset clear
-
00
0~ff
√
5|6|10
5.3.1.5
P5-34.2
SI terminal filtering time
ms
0
0~f
√
5|6|10
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......