220V + 10% (380V + 10%), then
check the supply voltage; if the
supply voltage is normal, then
servo
BB
state,
monitoring
U0-05, multimeter measurement
voltage * 1.414 > U0-05 (error
within 10V), then the servo
driver is faulty and needs to be
sent back for repair
1
E-041
Driver
power
down
Driver power off
Check the power supply
3
E-043
Bus
Voltage
Charging Failure
low voltage of power
grid
when
normal
power on
low voltage of power grid when
normal power on
Hardware damage
When the driver is on, please pay
attention to whether there is relay
actuation sound
4
E-044
Three
phase
voltage
input
phase loss
Three
phase
input
power supply is lack of
phase
Check the power supply
06
0
E-060
Module
temperature is too
high
(Module
temperature U-06
≥ 90
℃
alarm,
U-06 ≥ 70
℃
Warning)
Running under heavy
load for a long time
Re-consider the capacity of the
motor, monitor the U0-02 torque
during operation, whether it is in
the value of more than 100 for a
long time, if yes, please chose the
large-capacity motor or load
reduction.
Excessive
ambient
temperature
(1) Enhance ventilation measures
to reduce ambient temperature;
(2) Check whether the fan rotates
when the servo is enabled; when
the module temperature U-06
≥45
℃
, the fan opens.
Fan damage
Replace the fan
1
E-061 Motor overheat
Alarm
when
motor
temperature is higher
than 95
℃
①
Check whether the motor fan
is abnormal
②
Contact the manufacturer for
technical support
3
E-063
Thermocouple
disconnection
alarm
①
The
motor
thermocouple of 11kw
and above power is
disconnected
②
False
opening
detection
and
disconnection alarm of
motor below 11kw
Check the external thermocouple
connection;
Shield
thermocouple
disconnection alarm: P0-69.1 = 1
08
0
E-080
Overspeed (actual
speed ≥
P3-21/P3-22)
The maximum
forward speed is
P3-21 and the
maximum reverse
speed is P3-22.
Motor code not match
Check if the driver P0-33 is
identical with the motor code of
the motor label (the number after
MOTOR CODE), if not, please
change to the same one, then
power on again.
UVW wiring error
Inspection of motor UVW
wiring, need to be connected in
phase sequence.
Motor speed too fast
(1) The maximum speed limit
value P3-21/P3-22 was reduced.
(2) To confirm whether the
external force makes the motor
rotate too fast, whether the pulse
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......