wiring.
Poor gain adjustment
results
in
motor
vibration,
back
and
forth
swing
and
abnormal noise.
Readjustment of gain parameters
Driver
or
motor
hardware failure;
There are servo cross test or
motor empty shaft on site, F1-01
trial operation, F1-00 jog run can
not rotate uniformly;
Replace the new driver or motor
and
send
the
malfunction
machine
back
to
the
manufacturer for repair.
16
5
E-165
Anti-blocking
alarm
Judging that the
current motor
output torque is
greater than
P3-28/P3-29
(internal
forward/reverse
torque limit), and
the time reaches
P0-74 (unit ms),
and the speed is
lower than P0-75
(unit 1 rpm).
(1)
Machinery
is
impacted,
suddenly
becomes heavier and
distorted;
(2) When the brake of
the
motor
is
not
opened,
the
motor
moves;
(3)
The
parameter
setting is unreasonable.
(1) Eliminate the factors of
mechanical distortion. Reduce
load
(2) Measure the voltage of the
brake terminal and determine the
opening of the brake;
It is suggested to use servo BK
brake signal to control the brake
lock. If it is not servo control,
attention must be paid to the
timing of brake opening and
motor action.
(3) Monitor the actual output
torque range of U0-02 and check
whether the setting of P3-28/29
torque limit is reasonable. (After
version 3760, the output torque
limit setting parameters of anti
locked rotor alarm are P3-38 and
P3-39
)
20
0
E-200
Regenerative
resistance
overload
High
Voltage
Fluctuation in Power
Grid
Stable the input voltage
Selection
of
regenerative resistance
is too small
Replacement of higher power
regenerative resistors (refer to
chapter 1.4.1)
Acceleration
and
deceleration time is too
short
Extending
Acceleration
and
Deceleration Time
Hardware damage
The AC gear of the multimeter
measures the input value of the
servo LN (R/S/T), which is 220V
± 10% of the normal value. If the
power supply voltage is more
than 220V+10% (380V+10%),
check the power supply voltage;
if the power supply voltage is
normal, then in servo BB state,
monitor
U0-05,
the
voltage
measured by the multimeter *
1.414 < U0-05 (within 10V
error), then the servo driver is
faulty and needs to be sent back
for repair.
22
0
E-220
Communication
error of absolute
Motor matching error
Check if the motor matches
correctly
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......