occur.
Related parameters
Parameter
Meaning
Default
setting
Unit
Setting
range
Modify
Effective
P0-11
Pulse numbers per rotation *1
0
pul
0
~
9999
Servo
OFF
At once
P0-12
Pulse numbers per rotation *10000
1
pul
0
~
9999
Servo
OFF
At once
P0-13
Electronic gear ratio (numerator)
1
-
0
~
65535
Servo
OFF
At once
P0-14
Electronic gear ratio (denominator)
1
-
0
~
65535
Servo
OFF
At once
P0-92
Group 2 Electronic gear ratio
(numerator) low bit*1
1
-
1
~
9999
Servo
OFF
At once
P0-93
Group 2 Electronic gear ratio
(numerator) high bit*10000
0
-
1
~
65535
Servo
OFF
At once
P0-94
Group 2 Electronic gear ratio
(denominator) low bit*1
1
-
1
~
9999
Servo
OFF
At once
P0-95
Group 2 Electronic gear ratio
(denominator) high bit*10000
0
-
1
~
65535
Servo
OFF
At once
Note:
(1) P0-11~P0-14 is all about the parameters of electronic gear ratio, P0-11, P0-12 is group 1, P0-13,
P0-14 is group 2, but the priority of P0-11 and P0-12 is higher than that of P0-13 and P0-14. Only
when P0-11 and P0-12 are set to 0, the ratio of electronic gear P0-13 and P0-14 will take effect.
(2) When P0-11, P0-12, P0-13 and P0-14 are all set to 0, P0-92, P0-93, P0-94 and P0-95 will take
effect.
2. Calculation of Pulse Number per Rotation and Electronic Gear Ratio
Steps
Content
Description
1
Confirm
the
machine
specification
Confirm the deceleration ratio n:m(servo motor turns m
rotations while load turns n rotations), ball screw distance,
pulley diameter.
2
Confirm the encoder pulse
Confirm the servo motor encoder accuracy
3
Set the command unit
Determine the actual distance or angle corresponding to 1
pulse of the controller
4
Calculate the command pulses
the load shaft rotates 1 circle
Based on the determined command unit, calculate the
command quantity n of the load shaft rotating for 1 revolution.
5
Calculate
the
pulses
per
rotation M
Command pulse number of motor shaft rotating for 1 turn
M=N/(m/n).
6
Set the pulses per rotation
(P0-11/P0-12) or
Electronic
gear
ratio
(P0-13/P0-14)/(P0-92~95)
P0-11=M%10000
P0-12=M/10000
priority
n
N
m
M
14
0
P
13
0
P
resolution
encoder
resolution
encoder
Note:
(1) In step 6, the effective priority of the number of pulses per revolution is higher than the
electronic gear ratio, that is, when P0-11 ~ P0-12 are all 0, P0-13 ~ P0-14 will take effect. In special
cases, if the number of pulses per revolution is calculated as a decimal, the electronic gear ratio should
be considered.
(2) When P0-13 and P0-14 exceed the setting range, please divide the electronic gear ratio into
numerator and denominator. If the ratio still exceeds the parameter setting range, please use the second
gear ratio P0-92~P0-95. Only when P0-11~14 = 0, the second gear ratio takes effect.
(3) The resolution of DS5 series servo motor encoder is 131072 (17 bits) and 8388608 (23 bits).
(4) The command unit does not represent the machining accuracy. On the basis of the mechanical
accuracy, refining the instruction unit quantity can improve the positioning accuracy of the servo
system. For example, when using the lead screw, the mechanical accuracy can reach 0.01mm, so the
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......