5.4 Speed control
5.4.1 Speed mode general control
5.4.1.1 Soft start
Parameter
Meaning
Defaulted
setting
Unit
Range
Modify
Effective
P3-09
Soft Start
Acceleration Time
0
ms
0
~
65535
Servo bb
At once
P3-10
Soft Start
deceleration Time
0
ms
0
~
65535
Servo bb
At once
Soft start acceleration and deceleration time is suitable for mode 3/4/7. Smooth speed control can be
carried out when step speed instruction is input or internal setting speed is selected.
P3-09: Time from stop to rated speed
P3-10: Time from rated speed to stop
Target speed
Rated speed
Speed up time
P3-09
Speed down
time
P3-10
5.4.1.2 Zero clamp (/ZCLAMP)
1. Overview
This function is used when host controller uses speed command input and the servo system isn’t
configured the position loop. In other words, the function will be used when the motor must stop and
enter lock state even the V-REF input voltage is not zero.
When set ON the zero clamp function, it will configure the position loop inside the servo, the motor
will do zero clamp within ±1 pulse at this position. The motor will return to zero clamp position even it
is run by external force.
The present speed must be smaller than zero clamp speed when using zero clamp function, it can clamp
the motor shaft from moving. The motor will switch from speed mode to position mode when starting
the zero clamp function. At this time, rotate the motor shaft, it will return to the original position. It will
not return to original position in speed mode, because it has no position feedback.
2. Input signal setting
Parame
ter
Signal
Setting
Meaning
Range
P5-31
Zero clamp
/ZCLAMP
n.0000
(default)
Defaulted is not distribute to input
terminal
/Z-CLAMP
signal
is
distributed
to
input
terminal by parameter
P5-31,
Range:
0000-0014.
n.0002
Input signal from SI2 terminal
Содержание DS5L1 Series
Страница 1: ...DS5L1 series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 05 20200929 1 0 ...
Страница 2: ......
Страница 6: ......
Страница 33: ...Voltage DC 30V maximum Current SO1 DC 500mA maximum 400W and below servo can support SO others DC 50mA maximum ...
Страница 100: ...3 Set the auto tuning interface 4 Click ok to start inertia identification ...
Страница 106: ...3 set the auto tuning interface ...
Страница 112: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok ...
Страница 169: ...Appendix 9 Torque speed characteristic curve ...
Страница 170: ......