Communications and I/O
3 - 10
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
Output Definitions
This section describes the output signals that the MedWeld 4000 control
provides. At the right of the output names are abbreviations as they
appear on the DEP-100S (Data Entry Panel).
Valve outputs may be output in two ways:
Binary
or
Discrete
. The type
is set in I/O map
03 Valve Type
.
•
When set
binary
, the output is the weighted value of the binary
outputs. For example, 1 = BV1; 2 = BV2, 3 = BV1 + BV2 (because
1 + 2 = 3); 5 = BV4 + BV1 (1 + 4 = 5); etc.
•
When set
discrete
, only one of six possible valves will be output for
the sequence.
BINARY VALVE1/VALVE 1 Output
V1
BINARY VALVE2/VALVE 2 Output
V2
BINARY VALVE4/VALVE 3 Output
V4
BINARY VALVE8/VALVE 4 Output
V8
BINARY VALVE16/VALVE 5 Output
V16
BINARY VALVE32/VALVE 6 Output
V32
Turning on the discrete initiate for Valve #1, #2, #3, #4, #5 or #6
actuates the binary valve output 1, 2, 4, 8, 16 or 32, respectively.
NO FAULT Output
NFLT
This output is normally ON (to indicate that no fault conditions
exist). If the control shuts down as the result of a fault condition,
this output will be turned OFF.
FAULT Output
FLT
This output has only the FAULT state. The output is active HIGH
when no fault conditions are detected.
If the control detects certain error conditions, this output becomes
inactive until the fault is reset. To reset Fault or Alert conditions,
press the * key from the
Fault
display mode.
The Initiation On Fault setup parameter determines whether you
can initiate a new weld sequence when a fault condition has been
detected (and the FAULT output is active). For more information
about this parameter, see page 5-10.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...