Communications and I/O
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
3 - 11
M-032116 Programs #T03300, #T02300 and #T02400
ALERT Output
ALT
This output is normally OFF. It turns ON to indicate an alert
condition. Alert conditions are usually less serious than faults and
are normally used to warn the operator that maintenance is
required.
WELD / NO WELD Output
NWO
When the WELD/NO WELD input is opened, it energizes this
output (to indicate that the control is in No Weld Mode). If a valid
weld initiate is received while the control is in No Weld Mode, the
weld schedule will schedule normally, but weld current will NOT
flow.
WELD / NO WELD MISMATCH Output
WM
This output is active to indicate that the control is in Weld Mode
and the data entry device is in No Weld Mode.
WELD IN PROGRESS Output
WIP
The control turns this output ON and OFF in response to the output
control function. For more details, see “Output Control Functions”
on page 4-9.
END OF HOLD Output
EWS
This output turns ON after the control completes the number of
HOLD CYCLES programmed. The output remains active for the
number of OFF CYCLES programmed. (For example, setting OFF
CYCLES to 08 cycles holds this output active for 8 cycles.)
By disabling the OFF CYCLES (programming for 0 cycles), this
output remains on for five cycles before it is turned off. The output
remains on for a default interval of five cycles.
WELD COMPLETE Output
WCPL
This output is turned ON and OFF by the weld control in response
to Functions #50 and #51.
READY TO WELD Output
RTW
When active, this output indicates that the control is ready to weld
and will pass current if
•
The control is in Weld Mode,
•
NO faults exist,
•
The CONTROL STOP input is HIGH,
•
The WCU is synchronized with the line voltage,
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...