Fault Conditions
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
8 - 21
M-032116 Programs #T03300, #T02300 and #T02400
GROUND
Fault
(cont.)
Replace damaged current coil
interface cable.
NOTE: Replacing the current coil
interface cable could slightly
affect the inverter’s calibration
and make the primary current
displayed by the control inaccu-
rate. Preferably, re-calibrate the
unit after repair.
or
:
Field repair is possible. Repair a
damaged cable by comparing to
an undamaged cable; or contact
WTC Technical support for
connection information. NOTE:
This field repair could slightly
affect the inverter’s calibration
and make the primary current
displayed by the control inaccu-
rate. Preferably, re-calibrate the
unit after repair.
Defective sensors on
inverter.
Replace inverter.
Defective inverter
processor
Replace inverter.
V
dc
BUS
Fault
DEP-100S displays
DC BUS OVER
VOLTAGE FAULT.
Over- voltage on plant
mains.
Correct mains voltage.
Defective substation transformer.
Combination of ground
faults.
Find and correct ground faults.
Defective inverter
processor
Replace inverter.
LED On
Inverter
Symptom
Probable Cause
Corrective Action
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...