MedWeld 4000 Overview
MedWeld 4000 Operator’s Guide
Modified: 12/16/08
1 - 5
M-032116 Programs #T03300, #T02300 and #T02400
Type 1 Inverter Specifications
This section describes the Type 1 inverter ratings at two output levels:
Type 1 (60 Hz)
Inverter 600 Amp
This table lists the electrical ratings for output at 1,200 Hz from 60 Hz
mains frequency:
Specification or Quantity Rating
Minimum mains inductance per line
50
μ
H
Maximum choke size when adding inductance
50
μ
H per line
Mains voltage
240–480 VAC
(+10%, –15%)
Peak output current
600 A.
RMS current while operating
578 A.
RMS mains line current while operating
535 A.
Power
Factor
Nominal 81
%
KVA Input:
448
KW Output:
363
Duty Cycle
Maximum Duty Cycle
20%
Peak output
600 A.
Maximum Weld Time
0.7 seconds
Cooling
Water
Water flow rate
4 liters/minute or
1.06 gal / min
Water temperature
< 30 °C
Mean Time Between Failures (Mixed Welding and Power-on hours)
@ 10 % duty cycle
~ 1,250,000 hrs.
@ 20 % duty cycle
~ 500,000 hrs.
Operating Life
@ 10 % duty cycle
~ 105,000 hrs.
@ 20 % duty cycle
~ 50,000 hrs.
Cabinet ratings
9 %
duty cycle
RMS output current
173 A.
RMS mains line current
160 A.
Cabinet ratings at
10 %
duty cycle
RMS output current
183 A.
RMS mains line current
169 A.
Cabinet ratings at
20 %
duty cycle
RMS output current
258 A.
RMS mains line current
239 A.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...