Weld Schedules
4 - 16
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
93
INITIAL PF LIMIT: HI=nn% LOW=nn%
This function is used to generate a fault condition if the initial
power factor read during the test fire function (#39) does not fall
within the high and low limits programmed in this function.
The following conditions must be true when using this function:
•
Function #39 must appear in the weld schedule.
•
This must appear after the test fire function (#39) in the weld
schedule.
If the power factor read during the test fire was not within the range
programmed, the control generates an INITIAL P.F. OUT OF
RANGE fault.