Setup Parameters
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
5 - 9
M-032116 Programs #T03300, #T02300 and #T02400
This fault differs from the SHORTED CONTACTOR SHUNT
TRIP fault. It only checks for shorted contactors while welding,
versus
"runaway" inverters that fire on their own.
ANALOG NOT WITHIN WINDOW
(
T02300 only
)
(FAULT)
Certain versions of the program support analog I/O. When this
support is included, this setup parameter flags a fault condition if
the analog reading from a transducer is not within the specified
window tolerances. (For example, you might need to monitor the
position and height of die opening for projection welding.
However, the I/O functions and this parameter will accept any
analog transducer input: Height, displacement, force, pressure, etc.)
PRESSURE NOT ACHIEVED: (
T03300 only
)(FAULT)
Program #T03300 supports analog I/O through an analog card in
the chassis. Three setup parameters implement this support.
This fault occurs when the proportional valve pressure
(programmed by functions #08, #13 or #14), was not achieved
within the number of cycles programmed in Function #09 (WAIT
nn CY FOR PRESSURE ACHIEVED).
If the sequence contains more than one valve pressure setting, the
processor will only monitor the last pressure function contained in
the sequence.
This parameter is permanently set to the FAULT condition. You
CANNOT program it.
The following two parameters (along with Sec. Curr Coil Multiplier
(x1000)) support operation of the Secondary Current Interface Board
(SCIB):
SECONDARY CURRENT COIL/BOARD:
(
T03300 only
)
(FAULT)
This fault will occur under the following conditions:
•
If an error occurred while attempting to initialize or configure
the SCIB due to a malfunction on the SCIB board or an
improper connection to the weld timer.
•
If an error occurred during the secondary current calibration
process due to an improper connection to the secondary current
coil.
•
If an error occurred during the secondary calibration process
due to a loss of primary power (no zero-crossing
synchronization).
•
If an error occurred during the secondary calibration process
due to a missing current range jumper on the SCIB board.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...