9^cdQ\\Y^WdXU=UTGU\T$
""$
=_TYVYUT*'") #
=UTGU\T$ ?`UbQd_bµc7eYTU
= #"!!&@b_WbQ]cD ## D "# Q^TD "$
5HTXLUHG7RUTXHIRU(OHFWULFDO&RQQHFWLRQV
All electrical connections must be mechanically clean and secure,
without signs of wear, fretting, damage or chemical corrosion. These
requirements are CRITICAL for the high-voltage power connections to,
from and within the control.
This section lists the recommended torque specifications and cable sizes
for SCRs, circuit breakers and contactors. Refer to the NEC tables for
guidance in sizing cables. Refer to the following tables when making
electrical connections. Be sure to observe these specifications exactly.
5HTXLUHG7RUTXH
6&5V
Device
Suggested
Cable Size
Captive Nut Assy.
(Copper Lug or Bus
Direct to Device)
Cable Lug
Flexibar to Lug
or Device Tang
600 A. SCR
Darrah Q20008
Dynex MP02TT800
3.6 lb.-ft. (5 n-m)
N/A
N/A
1,200 A. SCR
Darrah Q20001P
Powerex ND431825
8 lb.-ft. (11 n-m)
N/A
N/A
1,650 A. SCR
Eupec T425N18KOF
Powerex LD431850
9 lb.-ft. (12 n-m)
N/A
N/A
1,800 A. SCR
Darrah Q20011
Dynex MP04TT1400
9 lb.-ft. (12 n-m)
N/A
N/A
1,750 A. SCR
Darrah DPH7844-468C
Darrah DPH7845-2.5
N/A
25 lb.-ft. (34 n-m)
3/8 in. bolt
16 lb.-ft. (22 n-m)
3/8 in. bolt
2,500 A. SCR
Darrah DPH7824-468F
Darrah DPH7406-469C
N/A
25 lb.-ft. (34 n-m)
3/8 in. bolt
16 lb.-ft. (22 n-m)
3/8 in. bolt
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...