Fault Conditions
8 - 12
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Proograms #T03300, #T02300 and #T02400
Isolation
Contactor
Off When
Needed
(See p. 5-5)
The isolation contac-
tor was not pulled in
by the control when
required by the weld
schedule.
The instruction to activate the
isolation contactor (Function
#52) was missing from the
weld schedule.
Verify that the schedule
contains Function #52.
Isolation contactor is con-
trolled by the weld control and
driven by a solid-state relay.
The weld processor signal is
based on the status of the
CONTROL STOP and WELD/
NO WELD Inputs. (Voltage
must be present at these
inputs to allow the weld pro-
cessor to open or close the
isolation contactor.)
Use the
I/O Status
display on
the DEP-100S to verify that the
inputs are high (= 1) when
required.
Verify that the Ready to Weld
signal is high (= 1) when
required.
For externally-powered
controls, an internal control
transformer fuse is blown.
Check fuses. Replace as
necessary.
The solid-state relay is faulty.
Replace solid-state relay.
The instruction to activate the
isolation contactor was exe-
cuted, but the control was
unable to pull in the contactor,
due to incorrect or loose wir-
ing to the output module.
Check the wiring diagram that
came with your control for
proper I/O designations. Verify
that all wiring connections are
secure.
Faulty output module.
Replace module.
Low Battery
(See p. 5-6)
The battery on the back of the processor card is low or
discharged.
Replace battery/processor
card.
(The battery is soldered in
place. Only qualified personnel
should attempt to replace the
battery in an ESD-safe
environment.)
High C-
Factor
(See p. 5-6)
The C-factor read
during the weld part
of the schedule
exceeded the value
programmed in
Function #97.
Unusual conditions in the
secondary.
Check for causes of shunting or
conducting water.
The High C-factor limit was
programmed too low.
Raise the high C-factor limit.
Message
Explanation
Possible Cause
Remedy
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...