Advanced Software Features
7 - 12
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
NOTE:
These parameters check different conditions. Shorted Cycle Limit checks
for shorted conditions when current is applied. Weld Current Shunting
checks for problems when primary current is NOT detected.
Retract Features
This section describes in detail how the retract operation is used to
provide support for the air only and air over oil cylinders. It also
describes how the operation of retract is affected by certain functions
and programmable setup parameters, which control the operation of:
•
Retract Mode
•
Initiate from Retract
•
Cylinder Type
WARNING!
For safety, the MedWeld 4000 ignores any
changes to these parameter settings until
power is removed from the control. The
control checks the status of these parameters
only at power-up.
Retract Mode
The Retract Mode setup parameter determines how the control responds
to the presence of an active RETRACT PILOT input.
•
UNLATCHED
tells the control to let the output for the Retract
Valve (or Blocking valve, for air-over-oil cylinders) follow the state
of the RETRACT PILOT input. The output will be active while the
input is active.
RETRACT PILOT Input
RETRACT VALVE Output
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...