MedLAN Connector (on the weld processor card):
WA R N I N G!
NEVER connect any of the communication ports
to the MDP- power wires. Damage to the ports or
other internal components may result.
&DEOH5RXWLQJ5HTXLUHPHQWV
Wire the MedLAN network ONLY in a “daisy-chain” method. NEVER
use “stub” wiring.
The maximum total length of the MedLAN network cable is 3,000 feet.
Up to 30 weld controls may be connected to a single MedLAN network.
The MedLAN cable wire ends terminate into MTSB (Phoenix)
connectors. Terminate the cable with this procedure:
1. Strip the cable jacket to 1 inch.
2. Remove foil shield strands outside the foil.
3. Cover the shield with heat shrink.
4. Cover the cable insulation end with one inch of heat-shrink tubing.
5. Strip 1/4 inch of insulation off each wire.
Designator
Pin #
Function
Wire Color
(BELDEN #9463)
MDL2
3
MedLan Line 2
Clear
MDLS
2
Line Shield
MDL1
1
MedLAN Line 1
Blue
Designator
Function
MDL1 - MedLAN Line 1
This is the TX/RX + line of the RS–485
signal. Attach it to the blue wire of the
cable.
MDL2 - MedLAN Line 2
This is the TX/RX – line of the RS–485
signal. Attach it to the clear or white wire
of the cable.
Shield
Connect the shield to the drain wire of
the cable.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...