Communications and I/O
3 - 12
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
•
System cooling is provided: The SCR OVER TEMP input is
closed
STEPPERS ARE RESET Output
SRST
This input resets all the steppers to Step 1 and the weld count to 0.
STEPPERS ARE RESET GROUP 1 Output
SRG1
STEPPERS ARE RESET GROUP 2 Output
SRG2
Either input will reset all the steppers in Group 1 or 2 to Step 1 and
the weld count to 0.
END OF STEPPER Output
EOS
This output is active when the stepper completes the final weld in
Step #5 of the profile. The program now issues the END OF
STEPPER fault. Electrode maintenance is required.
END OF STEPPER GROUP 1 Output
ESG1
END OF STEPPER GROUP 2 Output
ESG2
Either output is active when the stepper completes the final weld in
Step #5 of the stepper profile for Group 1 or 2. The program now
issues the END OF STEPPER fault. Electrode maintenance is
required.
STEPPER APPROACHING MAX Output
SALT
This output is turned ON when any assigned active stepper assigned
to one of these groups has entered Step 5.
STEPPER APPROACHING MAX GROUP 1 Output SAG1
STEPPER APPROACHING MAX GROUP 2 Output SAG2
Either output is turned ON when any assigned active stepper
assigned to one of these groups has entered Step 5.
PRESSURE SELECT 1 Output
PS1
PRESSURE SELECT 2 Output
PS2
PRESSURE SELECT 3 Output
PS3
PRESSURE SELECT 4 Output
PS4
These outputs are activated or de-activated when the MedWeld
4000 executes functions #56 (TURN ON PRESSURE SELECT #n)
and #57 (TURN OFF PRESSURE SELECT #n).
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...