Fault Conditions
8 - 8
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Proograms #T03300, #T02300 and #T02400
No Zero-
Crossing
Sync
(See p. 5-5)
The control is unable
to synchronize with
the AC line voltage.
No incoming voltage to the
control cabinet.
Verify incoming power to the
control’s circuit breaker with a
volt meter. If no power, check
for circuit break shunt trip or
other errors.
Failure of the incoming power
signal to reach the firing card,
(through its J3 connector) due
to loose or faulty wiring.
Check for loose wiring at the J3
connector on the firing card.
Repair as necessary.
Zero-crossing signal is not
reaching the weld processor
card, due to loose cable or
bad connector between the
firing card and the weld
processor card.
Secure the cable between the
firing card and processor card.
Check for bad connector, and
replace as necessary.
Faulty firing card.
Replace firing card.
Faulty weld processor card.
Replace weld processor card.
Overloading weld bus.
Re-distribute the weld bus load.
Brown-out of power source.
Correct power delivery problem.
System
Cooling
(See p. 5-6)
TRANSFORMER
OVER-TEMPERA-
TURE input was not
active when required
by the control, or the
SCR thermal switch
was tripped.
Defective SCR thermostat. Replace
thermostat.
Customer-supplied device
did not activate the TRANS-
FORMER OVER-TEMPERA-
TURE input when required.
Check device.
Loose/incorrect connections
to input module or in circuit.
Check for proper wiring
Insufficient water flow.
Check the water flow, access
holes, hoses and filters (if
used).
Faulty input module.
Replace module.
Weld
Interrupt
(See p. 6-5)
The control entered
No Weld mode while
executing a weld
schedule.
Robot or ladder logic de-
activated the WELD/NO
WELD Input.
Check robot or ladder to verify
that the input is being held
HIGH throughout the weld
schedule. (Use the DEP I/O
Status display to monitor the
status of this input.) Also check
the DEP I/O status.
Incorrect or loose wiring to
the input module.
Check for proper I/O designa-
tions. Verify that all wiring
connections are secure.
Faulty input module.
Replace input module.
Message
Explanation
Possible Cause
Remedy
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...