Advanced Software Features
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
7 - 21
M-032116 Programs #T03300, #T02300 and #T02400
Initiation From
Retract
The processor also provides a function which you can place in a weld
schedule to tell the control to check whether the selected cylinder is out
of retract. The function (VERIFY CYLINDER #n IS OUT OF
RETRACT) will abort the schedule and generate a Retract Pilot Fault if
the cylinder is NOT in the partial retract position.
NOTE:
The
RETRACT PILOT
fault should be programmed as an
ALERT
condition in the setup parameters, so the operator can place the valve in
the partial retract position and re-initiate the weld schedule.
If this condition is defined as a
FAULT
, the control will require a fault
reset before it can continue. (An exception is when the
Initiation On Fault
setup parameter is set to
ALLOW
, as described on page 5-10.)
If the weld schedule does NOT contain this function, the control will
allow you to execute a sequence with the gun in the full retract position.
When the control is fired from full retract, the Extend Sqz From Retract
(CY/2) setup parameter is added to the time the gun is closed under only
hydraulic pressure.
DEP-100S Programming Restrictions
Software version #T-96300-13 or greater has features that modify
operation of the DEP-100S (Data Entry Panel). These include changes
to the operation of the stepper, the ability to select No Weld operation
and restrictions on inserting and deleting certain functions.
As described in the
DEP-100S Programming Guide
, the information
you see will vary, based on the software contained in the weld processor.
This section describes how the DEP operation varies from the standard.
Weld/No Weld Status
The DEP’s Display Mode provides an option called
W/NW STATUS
.
(Refer to Chapter 3 of the
DEP-100S Programming Guide
.) It allows
changing the
software
setting at the weld processor from Weld to
NoWeld.
This feature is NOT supported by this version of the MedWeld 4000
software. The Display Mode does not provide the W/NW STATUS
option on its display.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...