Setup Parameters
5 - 20
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
MAXIMUM TIP DRESSES:
60
(0-99)
This parameter defines the maximum number of times the tips may
be dressed before the electrode caps must be changed. This sets the
starting value for the Tip Dresses Remaining counter.
Each time it receives the TIPS DRESSED input, the control
decreases the Tips Dresses Remaining counter by one. When the
maximum number of tip dresses remaining is zero, the control
activates the CAP CHANGE REQUEST output. This indicates that
the tips require maintenance.
Setting this parameter to zero disables the tip dress operation.