Communications and I/O
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
3 - 21
M-032116 Programs #T03300, #T02300 and #T02400
Output Abbreviations
On the LCD panel of the MedWeld 4000 or DEP-100S, the FieldBus
and DiscreteDiscrete outputs appear with these abbreviations:
VALVE1 / BINARY VALVE 1 .................................V1
VALVE2 / BINARY VALVE 2 .................................V2
VALVE3 / BINARY VALVE 4 .................................V4
VALVE4 / BINARY VALVE 8 .................................V8
VALVE5 / BINARY VALVE 16 ...............................V16
VALVE6 / BINARY VALVE 32 ...............................V32
NO FAULT Output..................................................NFLT
FAULT Output ........................................................FLT
ALERT Output........................................................ALT
WELD / NO WELD ................................................NWO
WELD / NO WELD MISMATCH Output ................WM
WELD IN PROGRESS ..........................................WIP
END OF HOLD Output...........................................EWS
WELD COMPLETE ...............................................WCPL
READY TO WELD ................................................RTW
STEPPERS ARE RESET .....................................SRST
STEPPERS ARE RESET GROUP 1 ....................SRG1
STEPPERS ARE RESET GROUP 2 ....................SRG2
END OF STEPPER ...............................................EOS
END OF STEPPER GROUP 1 .............................ESG1
END OF STEPPER GROUP 2 .............................ESG2
STEPPER APPROACHING MAX .........................SALT
STEPPER APPROACHING MAX GROUP 1 ........SAG1
STEPPER APPROACHING MAX GROUP 2 ........SAG2
PRESSURE SELECT 1 ........................................PS1
PRESSURE SELECT 2 ........................................PS2
PRESSURE SELECT 3 ........................................PS3
PRESSURE SELECT 4 ........................................PS4
INTENSIFICATION VALVE Output ........................INTV
INITIATION ACKNOWLEDGE Output ..................IACK
RETRACT 1 ..........................................................RV1
RETRACT 2 ..........................................................RV2
NONE
Setting the Word Size
On the DEP-100S, you can specify the word size for I/O in either
FieldBus or DeviceNet communications. Do this under the
Program
menu and
I/O Mapping
option.
Set the word size for one of these choices:
•
0
disables communications.
•
1
sets the word size to 16 inputs or 16 outputs, to supply one
discrete I/O board.
•
2
sets the word size to 32 inputs or 32 outputs, to supply two
discrete I/O boards.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...