5
The MedWeld 4000 provides a number of programmable
setup
parameters
. They allow for customizing the control to meet your
application requirements.
These parameters “inform” the control about its operating environment.
They also define the hardware (such as the type of transformer used and
its turns ratio), and describe acceptable limits on the ranges of weld
parameters (such as secondary current, power factor and C-factor).
Some parameters define the severity of fault conditions (as either
FAULT or ALERT). They tell the control how to respond when it
detects a fault condition:
•
FAULT
tells the control to turn OFF the NO FAULT output, or turn
ON the FAULT output. This indicates that a fault condition was
detected.
Fault conditions normally inhibit initiation of a weld schedule.
(Refer to the Initiation On Fault setup parameter on page 5-10.)
•
ALERT
tells the control to activate the ALERT output. An alert
condition generally will not inhibit initiating a weld schedule.
•
NONE
tells the control to log that the condition was detected, but
neither output is activated. This condition will not inhibit initiation
of a weld schedule.
Parameter settings are programmable (with some exceptions). However,
the
list
of parameters is fixed. You CANNOT remove a parameter from
this list.
You can change the value assigned to a parameter from the DEP-100S
Programming Device,
WSS
(Weld Support System) or
WebVIEW
. (Refer
to “Programming the Weld Processor” on page 2-12 for further
information on these programming options.)
NOTE:
To protect the operator or equipment, some parameters are NOT
programmable. For these, you CANNOT change the setting or value.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...