Fault Conditions
8 - 20
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Proograms #T03300, #T02300 and #T02400
GROUND
Fault
DEP-100S displays
OUTPUT GROUND
FAULT.
Inverter cable connections
have become loose.
Check all cabling to verify that
connections are tight and no
accidental grounding of cables is
occurring. Check weld trans-
former primary cables, all cable
connections in the control, the
cabling to the line side of the
weld control circuit breaker, the
connections in the bus plug
(including any junction boxes, if
used) and the connection of the
bus plug to the weld bus.
Primary cable to weld
transformer is defective.
See Inverter Technical
Reference manual,
M-034045 for Primary
Cable troubleshooting
flowchart.
Replace cable as necessary.
Weld transformer is
defective.
See
Inverter Technical
Reference manual
, M-
034045 for
Check Trans-
former
troubleshooting
flowchart.
Primary shorted to ground:
Replace transformer.
Primary shorted to secondary:
Replace transformer.
The two coils used to
check for ground fault are
located on inverter out-
puts H1 and H2. Check the
two cables, the current coil
interface cables, that con-
nect the inverter board to
the coils. Check the cables
for:
Disconnection or unseat-
ing from the coil. (Ground
fault occurs on every
weld);
or
Connect unseated cable to coil
or to processor.
Wires between coil and
processor board are
broken (usually during
weld transformer primary
cable installation to
inverter. (Ground fault on
every weld.)
WTC recommends replacing the
inverter.
LED On
Inverter
Symptom
Probable Cause
Corrective Action
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...