background image

No.4 

Backcheck

No.1 Closing

No.2 Latching

90°

1

2

3

4

Fast Slow

Adjusting the force

No.3 Delayed Action

Using the templates provided, mark and 

drill pilot holes into the door and frame.

Attach the armset to the mechanism ensuring the 

pre-loading requirement has been completed.

Using the templates provided, fix the mechanism to the door 

as well as the armset and any necessary brackets.

Operate door closer in order to check operation.

No.2

No.1

No.3

No.4

65

°

Regular Fixing

Installation and Maintenance Instructions:

Maintenance

1.Once the unit has been correctly 

fitted it is recommended that 
periodic checks (every six 
months) are carried out to ensure 
all fixings are tight and the door 
closes freely and positively into 
the frame, without slamming.

2.A light oil lubricant (non-graphite) 

should be applied to the moving 
joints and exposed pivot points.

After Installation

1.When the closer operates to close 

the door from its maximum opening 
position, it should ensure the lock 
latchbolt and any seals are overcome 
and the leaf returned into its frame.

2.When the door is slightly open and 

the latch bolt resting against the 
strike, release the door to ensure the 
leaf fully closes into its frame.

Warning

1.Please note the minimum power size requirement for fire / smoke 

door assemblies is 3 as required by Approved Document B.

2.Do not install mechanical hold open devices on fire / smoke door 

assemblies.

3.Take care not to exceed the maximum opening angle as detailed 

above.

4.Care and attention must be taken when adjusting any of the units 

control valves to avoid damage through over adjustment.

5.All  our Door Closer units are sealed for life and the internal 

components assembled under high load, therefore, tampering 
with the mechanism is to be strictly avoided.

Installation Instructions: Please refer to actual size template for exact fitting dimensions 

Pre-Loading of Arm

For the unit to provide the optimum performance and overcome any resistance 
upon closing it is recommended that the armset is “pre-loaded” To pre-load, 
reposition the fixing angle of the arm onto the mechanism so that the end of the 
closing cycle would be past the stop position, as indicated below.

Adjustment Details

This unit is a power adjustable mechanism.  Power / force adjustment is carried 

out by a single adjustment valve in the end of the mechanism. The unit is 

pre-set in the factory at EN size 3.  Please see table below for adjustment 

details for each power size.

The following adjustment valves have a maximum adjustment of 1 full turn per 

valve. 

PLEASE NOTE

 over adjustment will damage the mechanism and/or the 

performance of the door closer and invalidate its guarantee.

Adjust Backcheck (valve #4) and the Delayed Action (valve #3) before 

adjusting the Closing Speed (valve #1) and Latching Action (valve #2).

90°

90°

Before

After

Backcheck Adjustment

To increase the backcheck action, turn the valve clockwise. To decrease, or  to turn 

off backcheck, turn the valve counter clockwise.

Adjust the Closing & Latching speed.

1.The door closer can control two different speeds.

2.The No.1 speed-adjusting valve controls  the Closing speed, and the No.2 speed 

   adjusting valve controls the Latching speed.

Delayed Action

To delay the closing action of the unit adjust valve No.3

ISSUE 02:08/17

10608 ZINS-F1128-9Z

www.gu-secury.com

Fixing Instructions for : L-10002-04
Door Closer Power Selectable EN 2-5

APPROVED

PRODUCT

CF 5514

CPR

AD5326

1121

17

BS EN1154:1997+ A1:2002

4 8 52 1 1 4

www.gu-secury.com

Fixing in Fig.1 / Fig.61

3

Max.

Door width

Max.

Door weight

950mm

60Kg

Power

size

180°
180°

Door opening

Max.

4

1100mm

80Kg

5

1250mm

100Kg

180°

8CCW
0

Number of turns

7CW

Factory preset  

CW:Clockwise  CCW:Counterclockwise

2

180°

850mm

40Kg

8CCW

Отзывы: