background image

236

50

50

175

43

54

48

130

10

11

Main arm

Link arm

parallel arm bracket 

Using the templates provided, fix the mechanism

to the door as well as the armset and parallel arm 

bracket.

Using the templates provided, mark and drill pilot 

holes into the door and frame.

Make sure the main arm is parallel to the door. Then

attach the connecting arm.

1

2

3

4

Rotate the bottom pinion to approximately 100° 

with a wrench as illustrated and then assemble 

the main arm.

Parallel Fixing

Ref 100°

Main arm

Link arm

236

50

50

175

43

54

48

130

10

11

parallel arm bracket 

www.gu-secury.com

Fixing Instructions for : L-10002-04
Door Closer Power Selectable EN 2-5

Fixing in Fig.66

3

Max.

Door width

Max.

Door weight

950mm

60Kg

Power

size

130°
130°

Door opening

Max.

4

1100mm

80Kg

0
7CW

Number of turns

Factory preset  

CW:Clockwise  CCW:Counterclockwise

Fixing in Fig.66

3

Max.

Door width

Max.

Door weight

950mm

60Kg

Power

size

130°
130°

Door opening

Max.

4

1100mm

80Kg

0
7CW

Number of turns

Factory preset  

CW:Clockwise  CCW:Counterclockwise

APPROVED

PRODUCT

CF 5514

CPR

AD5326

1121

17

BS EN1154:1997+ A1:2002

4 8 52 1 1 4

www.gu-secury.com

Отзывы: