background image

Operating Manual

PUK U4

Содержание PUK U4

Страница 1: ...Operating Manual PUK U4...

Страница 2: ...OPERATION THE GENERAL SAFETY REQUIREMENTS AND PERSONAL BODY PROTECTION CHAPTERS MUST BE READ BEFORE COMMISSIONING Please keep these operating instructions safe The equipment produced by Lampert Werkt...

Страница 3: ...election of the TIG welding parameters Pg 11 6 2 Help function Pg 12 6 3 Programming Pg 12 6 4 Loading saved WIG welding programs Pg 13 6 5 Resistance welding mode Pg 13 7 WELDING INSTRUCTIONS 7 1 Int...

Страница 4: ...the mains and welding currents can be a source of danger Always remove the mains plug when exchanging the LED unit Only use original replacement LED units from Lampert The device must be isolated from...

Страница 5: ...in protection class 10 In addition to light and thermal radiation which can cause dazzling and burning the electric arc also emits UV radiation With insufficient protection this invisible ultraviolet...

Страница 6: ...ET FOR LED MICROSCOPE ILLUMINATION 6 TYPE PLATE 7 SERIAL NUMBER 8 PROTECTIVE GAS CONNECTION ARGON GAS for 6 0 mm diameter pressure hose 9 APPROVED MAINS VOLTAGE FOR THIS DEVICE 10 USB SOCKET FOR SERVI...

Страница 7: ...up hand tight do not use a tool to tighten The correct length for the electrode can easily be checked and corrected if necessary by means of the milled marks on the handpiece clamping arm Fig 4 Now re...

Страница 8: ...interocular distance should be individually set for each user FOCUSING Mount a welding handpiece with clamped electrode into the supporting arm Rotate the focusing knob 22 to a medium focus range Adj...

Страница 9: ...as resistance welding devices 29 CONNECTION SOCKET FOR HAND PIECE 30 SOCKET 6 mm socket for connecting the blue contact terminal for resistance welding as well as resistance welding devices TOUCHSCREE...

Страница 10: ...d custom settings c Resistance welding mode d Settings In user level TIG welding it is possible to use the arrow keys to scroll back and forth between the various pages e g between the preconfigured p...

Страница 11: ...GS The Settings user level can be used to modify basic settings and launch various test functions Gas Test Pressing the corresponding button causes the gas valve to be opened This function is importan...

Страница 12: ...welding time Welding times of no more than 4ms are recommended here With many alloys and other highly conductive metals a longer welding time can be advantageous in order to avoid hot cracks starting...

Страница 13: ...e Use identical alloy wire with a diameter of 0 3 to 0 4 mm Particularly low energy fusing of thin welding wires of a max 0 25 mm PUSHING TOUCHING THE RESPECTIVE BUTTON FOR AN EXTENDED PERIOD BRINGS U...

Страница 14: ...FUNCTION OF THE EYE PROTECTION FILTER AS DESCRIBED IN CHAPTER 5 5 FILTER TEST IF THE EYE PROTECTION FILTER SHUTTER FAILS TO SWITCH OVER FROM LIGHT TO DARK THEN IT MUST BE IMMEDIATELY EXCHANGED BY AUT...

Страница 15: ...e black When the two parts are touching the welding process can be triggered using the foot switch The hand piece is not used during this process The required welding power is determined by the streng...

Страница 16: ...HAT ARE NOT DESCRIBED IN THESE OPERATING INSTRUCTIONS ARE NECESSARY THEN CONTACT YOUR DEALER WARNING IF FUSES REQUIRE EXCHANGING THEN THEY MUST BE REPLACED WITH FUSES OF THE SAME TYPES AND VALUES THE...

Страница 17: ...ly in dry rooms Operating temperature Lamp LED unit Protection class Insulation class Protection type Weight 5 C to 40 C 2 5W 800mA III B IP 20 3 6 Kg 9 3 OPTICAL DATA MICROSCOPE Lens Ocular Working d...

Страница 18: ...load Tungsten inert gas welding Earthing earth Nominal welding current Power consumption under max load Power consumption under nominal load Cyclic duration factor Single phase transformer Keep away f...

Страница 19: ...firmly 7 Oxidation and rusting Excessive gas pressure Reduce flow rate approx 2 l min is recommended 8 Severe oxidation of the welding points Incorrect shielding gas Use inert shielding gas Argon 4 6...

Страница 20: ...ocusing knob REPAIR If the stereo microscope requires repair or adjustment by qualified personnel we recommend sending it back to the dealer authorized customer service in its original packaging Inclu...

Страница 21: ...e disposal of used electrical and electronic equipment discarded electrical devices must be separated and collected and sent for recovery in an environmentally friendly manner 13 EC DECLARATION OF CON...

Страница 22: ...Born in Germany Lampert Werktechnik GmbH Ettlebener Stra e 27 D 97440 Werneck Tel 49 9722 9459 0 mail lampert info www lampert info Rev 4 0...