Advanced Software Features
7 - 18
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
The blocking valve is dis-engaged (based on the CYLINDER
TYPE setup parameter: normally open or normally closed), to
allow the oil to flow back into the reservoir.
This is illustrated in the drawing below:
Example Weld Schedule: Air Over Oil Cylinder
Operation
82
LINEAR STEPPER #01 ASSIGNED (0=OFF)
80
VERIFY CYLINDER #1 IS OUT OF RETRACT
62
REPEAT (AT NEXT FUNCTION)
17
TURN ON ADVANCE VALVE #1 SQZ
20
CY
18
TURN ON INTENSIFY VALVE SQZ
10
CY
20
WELD 10 CYCLES 50%I
78
PROCESS WELD FAULTS
03
HOLD 05 CYCLES
19
TURN OFF INTENSIFY/ADV VALVE #1
04
OFF 10 CYCLES
82
LINEAR STEPPER #00 ASSIGNED (0=OFF)
80
VERIFY CYLINDER #n IS OUT OF RETRACT
62
REPEAT (AT NEXT FUNCTION)
15
TURN ON ADVANCE VALVE #1 SQX 20 CY
16
TURN ON INTENSIFY VALVE SQZ 10 CY
01
SQUEEZE 00 CYCLES
24
PREWELD 00 CY 30%I
02
COOL 10 CYCLES
20
WELD 10 CYCLES 50%I
03
HOLD 05 CYCLES
17
TURN OFF INTENSIFY/ADV VALVE #1
04
OFF 10 CYCLES
Normally-Open (NO) Blocking Valve, partial to full retract:
Blocking Valve #n
Advance Valve #n
t
= PARTIAL RETRACT #n DELAY
full retract
partial retract
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...