Communications and I/O
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
3 - 9
M-032116 Programs #T03300, #T02300 and #T02400
RETRACT PILOT #1 Input
RT1
RETRACT PILOT #2 Input
RT2
This input changes the state of the RETRACT VALVE #1 (or #2)
output. How this output reacts to the RETRACT input depends on
the settings established for the Retract Mode and Retract Cylinder
setup parameters.
•
When set to
UNLATCHED
, the RETRACT VALVE output
follows the state of the RETRACT input. The valve output is
active while the input is active.
• When
setting
LATCHED
retract mode, the RETRACT input
changes the state of the RETRACT VALVE output. The first
pulse from the input activates the valve output. The second
pulse from the input de-activates the output.
•
With NONE selected, the control ignores the RETRACT input.
The Retract Cylinder setup parameter defines the retract cylinder as
either AIR-NORMAL, or AIR-INVERTED, AIR/OIL-
NORMALLY-OPEN or AIR/OIL-NORMALLY-CLOSED.
• AIR-NORMAL
indicates
that the output is turned
OFF
to close
the gun.
•
AIR-INVERTED indicates that the output is turned
ON
to
close the gun.
•
AIR/OIL-NORMALLY OPEN indicates that the output is
turned
OFF
to close the gun.
•
AIR/OIL-NORMALLY CLOSED indicates that the output is
turned
ON
to close the gun.
For a detailed explanation of operation in retract, see “Retract Features”
on page 7-12.
Содержание MedWeld 4000
Страница 77: ...9 cdQ Y W dXU UTGU T _TYVYUT UTGU T UbQd_bµc 7eYTU b_WbQ c D D Q T D This page is intentionally left blank ...
Страница 153: ...Weld Schedules 4 54 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 255: ...Hardware Troubleshooting 9 10 Modified 9 17 08 MedWeld 4000 Operator s Guide M 032116 Programs T03300 T02300 and T02400 ...
Страница 257: ...Application Note Current Compensation 2 ML 010041 Application Note Current Compensation ...
Страница 261: ...Application Note Cascade Welding 4 ML 010041 Application Note Cascade Firing ...