background image

 

HUNTER-PRO 32 

Ver. 3.8

 

Intruder Alarm System

 

RXN-9/416 User Guide 

       

 

 

 

 

 

PIMA Electronic Systems Ltd. 

5 Hatzoref Street, Holon 58856, Israel 

 +972-3-5587722 

 +972-3-5500442 

 

[email protected]

 

 

http://www.pima-alarms.com

 

Содержание HUNTER-PRO 32 RXN-9/416

Страница 1: ...NTER PRO 32 Ver 3 8 Intruder Alarm System RXN 9 416 User Guide PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel 972 3 5587722 972 3 5500442 support pima alarms com http www pima alarms com ...

Страница 2: ...right to modify this manual or any part thereof from time to time without serving any prior notice of such modification Please read this manual in its entirety before attempting to program or operate your system Should you misunderstand any part of this manual please contact the supplier or installer of this system Copyright 2006 by PIMA Electronic Systems Ltd All rights reserved You can contact u...

Страница 3: ...urity you should test the HUNTER PRO 32 Intruder Alarm System once a week For any further questions please do not hesitate to contact your local PIMA Distributor or PIMA directly at PIMA Electronic Systems Ltd Tel 972 3 558 7722 Fax 972 3 550 0442 Email support pima alarms com Up to date literature is available to download from our website www pima alarms com Main Features HUNTER PRO 32 9 zones in...

Страница 4: ... 416 has 16 LEDs as well as more fault indications NOTE It is possible to purchase from PIMA a keypad with tamper switch that supervises the keypads connected to the system RXN 416 The RXN 416 keypad has 16 red zone LEDs a red Fault LED and a green Armed LED The 16 zone LEDs are also used for displaying faults as described below Armed Indicator The green ARMEDLED provides the system arm status as ...

Страница 5: ...s OFF System partition is Disarmed ON Systemis in Arm mode Blinking System partition is in Entry or Exit Delay Mode BACK END ENTER NEXT INFO Lid Fault Notification The red FAULT LED blinks when a fault is detected Zone Status The status of each zone is listed by its number Faults Long press on the INFO key changes LED display to system faults see Faults Table for details Bypass The red BYPASS LED ...

Страница 6: ...he zones are closed and flash when the zones are open Normal Display in User Mode Each LED corresponds a zone numbers 1 9 RXN 9 1 16 RXN 416 Zone LED Display Status OFF Zone is closed Flashing Zone is open ON Zone caused an alarm Operation LEDs indication in User Mode Operation LEDs Status Fault ON Fault with the system Use the next section to display fault s Armed ON System is armed Bypass ON One...

Страница 7: ...ads RXN 416 These faults should be fixed by a qualified technician installer Programming connection error The keypad ID should be reprogrammed Numerical LEDs are flashing left to right RXN 9 416 Programming connection error The keypad is disconnected from the panel Numerical LEDs are flashing right to left RXN 9 416 User Menu Display Accessing User Menu by entering Master Code Enabled User Code or...

Страница 8: ...irmation beep is heard System Access Codes The system can be operated using each of the following codes Master Code User Code and Short Code The Short Code is only useful for arming the system There are two additional unique codes Duress Code and Relay Code The Duress Code will disarm the system and at the same time will send a duress event to the monitoring station The Relay Code will activate th...

Страница 9: ...one of these codes the green Armed LED will flash and a constant beep once per second will be heard from the keypad during the exit delay period At the end of the exit delay the green control LED shall stop to blink and turn ON and the beep will stop Arming with Open Zones When activating the system with one or more opened zones that are not Exit Delay zones the keypad will beep fast two beeps per...

Страница 10: ...OME 2 NOTE Exit Delay in HOME 1 and HOME 2 can be disabled by the installer Entering the User Menu From this point forward every time Master Code is mentioned in operation and or programming the explanation is the same for Enabled User Code and for User Code or Installer Code that accesses the User Menu by long press of the key before entering the code All these will access the User Menu On RXN 9 ...

Страница 11: ... 9 only is ON there is one or more user bypassed zones in the system To Bypass a zone Master Code LED 3 constantly ON LED 1 blinks Zone number the pressed zone LED starts blinking1 the pressed zone LED stops blinking and the next sequential zone starts blinking NOTE When Bypass mode is executed it is effective until system is disarmed To Rearm a bypassed zone Master Code LED 3 constantly ON LED 1 ...

Страница 12: ...ponse to a panic event for example calling the Monitoring Station or your private telephone number Consult your installer about programming a Panic Response Keypad Audible Tones Disable and simultaneously NOTE When the keypad s Audible Tone feature is disabled all audible tones and indications with that keypad are silenced Enable and simultaneously until you hear a beep Arming Disarming with a Key...

Страница 13: ...o following tones Continuous tone System is disarmed Beeping sound System is armed NOTES The system will not identify commands from the telephone while sounding the confirmation tone It is important to wait until the confirmation tone is finished before pressing the telephone keys that control the system The alarm system confirms the command was received by two short beeps There are two modes for ...

Страница 14: ...no 2 28 Output no 8 31 Expander no 1 relay 32 Expander no 2 relay 33 Expander no 3 relay NOTES During communication time between system and telephone the following display will appear on the keypad Other keypad in use If the system receives no command within a minute it will disconnect from the line and return to normal operation Each time an additional minute of listening listen in function is re...

Страница 15: ...m but depending on the user s authorization level the user can also enter the User Menu and perform various tasks as changing other users settings program telephone numbers temporarily bypass zones etc HUNTER PRO 32 holds up to 24 different User Codes 4 to 6 digits each NOTE An LCD keypad is required to program user names a time frame in which he she will be able to disarm the system allocated to ...

Страница 16: ...D 8 constantly ON LED 2 blinks DATE DD MM YY NOTE Enter time in 24 00 HH MM format and date in day month year format The system will not accept meaningless data such as 25 25 time Example To program 6 35 PM October 21st 2005 do Master Code LED 8 constantly ON LED 1 blinks LED 8 constantly ON LED 2 blinks Automatic Arming The system can be automatically armed with one of the following three options...

Страница 17: ...stem will begin regular arming process including exit delay and beeps from the keypad Programming Auto Arming at Preset Time Master Code LED 4 constantly ON LED 4 constantly ON LED 1 blinks Time in which the system will be armed HH MM NOTE To cancel Auto Arming the Automatic Arming programming needs to be repeated and the time to be set as 00 00 Programming Auto Arming after Silence Time is Termin...

Страница 18: ...t to stop receiving the system s report All Private Dialer Telephone Numbers have been dialed twice Programming Telephone Numbers It is possible to combine the process of entering deleting changing programmed telephone numbers once in the Telephone Menu Master Code LED 6 constantly ON LED 1 blinks Telephone number no 1 LED 6 constantly ON LED 2 blinks Telephone number no 2 LED 6 constantly ON LED ...

Страница 19: ...s Zone number the pressed zone LED starts blinking2 to confirm or to release to exit For temporary cancellation of Chime see Chime Mode on page 12 Smoke and Fire Detectors Alarm In case an alarm is triggered due to smoke fire detectors press and hold the key until a confirmation sound is heard in order to reset and release the detector NOTE The smoke detector returns to normal operation mode after...

Страница 20: ...HUNTER PRO 32 User Manual LED Keypads 20 ZONES DESCRIPTION Zone Partition Zone Name Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P N 4410212 Rev D July 2006 ...

Отзывы: