MODE B - Enhanced control
The enhanced mode enables full control of all systems outputs.
6.
Execute command by pressing keys combination:
N
to activate an
output;
K
to deactivate an output. The command is followed by the
output code as described in the following table.
General
Control panel
Output card
Expanders
00 - Disable
dialer
*01
- Arm
#01
- Disarm
04 - Home 1
07 - Home 2
08 - Listen-in
11 - Siren 1
12 - Siren 2
13 - Relay
14 - SMOKE
detector
15 - ON/OFF
output
16 - ALARM
output
21 - Output
no.1
22 - Output
no.2
.
.
.
.
28 - Output
no.8
31 - Expander
no.1 relay
32 - Expander
no.2 relay
33 - Expander
no.3 relay
NOTES
During communication time between system and telephone, the following
display will appear on the keypad:
Other keypad in use
If the system receives no command within a minute, it will disconnect from the
line and return to normal operation.
Each time an additional minute of listening (listen-in function) is required, the
N
0
8
keys should be pressed again.
Examples:
To disarm the system:
Dial and wait for confirmation tone
Master Code
wait for confirmation
tone
(on telephone keys)
K
0
1
To activate output No.5 on output card OUT-1000:
Dial and wait for confirmation tone
Master Code
wait for confirmation
tone
(on telephone keys)
N
2
5