Supervision
Self Supervision
HighPROTEC
devices are continuously monitored and supervised through different methods during normal
operation as well as during start-up phase.
Results of this supervision may be:
•
messages appearing within event-recorder (from release 1.2 or later);
•
indications within the display or Smart View;
•
corrective measures;
•
disabling of protection functions;
•
restart of the device;
or any combination out of these.
In case of failures that cannot be corrected immediately, three restarts within 20 minutes are accepted before the
device will be deactivated. The device should be removed in for service in such case. Contact data and
address can be found at the end of this manual.
In case of any failures, the recorders of the device should be left untouched to ensure an easy diagnosis and
proper repair at the factory. Besides the records and visible indications to the customer there exists internal
information about failures. These allow service personnel to make a detailed analysis of files with failure reports,
at least at factory site.
Self supervision is applied by different functions at different cyclic or non-cyclic timings to the following parts and
functions of the device:
•
faultless cyclic execution of software;
•
functional capability of memory boards;
•
consistency of data;
•
functional capability of hardware sub-assemblies; and
•
faultless operation of the measuring unit.
Faultless cyclic operation of software is supervised by timing analysis and checking results of different functions.
Errors of the software function (watchdog function) lead to restarting the device and switching off the self-
supervision relay (life-contact). Also the System-OK LED will blink red, after three unsuccessful attempts to
restart the device within a time-period of 20 minutes.
The main processor cyclically monitors the operation of the signal processor and initiates corrective actions or
restart of the device in case of faulty operation.
Data and files are generally secured against unintended overwriting or faulty changes by check sums
The measuring unit continuously checks the measured data by comparing received data with data from a
second channel sampled in parallel.
The auxiliary voltage is monitored continuously. I f the voltage of one of the different supply circuits falls below a
certain threshold, a restart of the device is initiated. If the voltage staggers around the threshold, the device also
starts again after several seconds. Additionally the level of all internal supply voltage groups are continuously
monitored.
Independent of these separate monitoring functions, the intermediate voltage circuit is buffered until all important
and relevant operational and fault-data have been saved and the device initiates a restart.
Page 420
EN MRM4 01/11
Содержание MRM4
Страница 1: ...MRM4 HighPROTEC Motor Protection Device Manual DOK HB MRM4E...
Страница 3: ...Order Code EN MRM4 01 11 Page 3...
Страница 18: ...Important Definitions Page 18 EN MRM4 01 11 41 SG Prot ON 42 SG ON Cmd SG Prot ON SG ON Cmd...
Страница 115: ...Navigation Operation Navigation Operation EN MRM4 01 11 Page 115 1 2 3 5 7 6 8 10 9...
Страница 162: ...Recorder Name Description I 2 TripCmd Signal Trip Command Page 162 EN MRM4 01 11...