Communication Protocols
Direct Commands of the IRIG-B00X
Parameter
Description
Setting range
Default
Menu path
Res IRIG-B Cr
Resetting of the
Diagnosis Counters:
IRIG-B.
inactive,
active
inactive
[Operation
/Reset
/Counter]
Global Protection Parameters of the IRIG-B00X
Parameter
Description
Setting range
Default
Menu path
Function
Permanent activation or
deactivation of
module/stage.
inactive,
active
inactive
[Device Para
/IRIG-B]
IRIG-B00X
Determination of the
Type: IRIG-B00X. IRIG-B
types differ in types of
included “Coded
Expressions” (year,
control-functions,
straight-binary-seconds).
IRIB-000,
IRIB-001,
IRIB-002,
IRIB-003,
IRIB-004,
IRIB-005,
IRIB-006,
IRIB-007
IRIB-000
[Device Para
/IRIG-B]