Chapter 6 - Additional Configuration Options
Configure Networking Services
4.
Using the drop-down list, select the
Port
used for the HTTP connection to the S3 service.
Note:
The HTTPS connection is always available on port 443.
5.
Enter a value in minutes in the
Auto-Activate Timeout
entry field. This value specifies the
amount of time that must pass between the S3 data path backend shutdown and the
restart before it will not be auto-activated. For example, if the system is powered off for
longer than the specified timeout value, you must manually restart the S3 data path
backend after powering on the system.
Notes:
• To manually start the data path backend, see
.
• If the
Auto-Activate Timeout
is set to 0, the data path backend will never auto-
activate.
6.
Using the drop-down menu, select a behavior for
Auto-Inspect
. This setting configures
whether tape inspections are performed by the system based on a tape’s last known
state, or each time the BlackPearl is initialized.
Value
Description
Full
Tapes are scheduled for inspection if an inspection is
necessary given the tape's current state, as well as every
time the BlackPearl system is initialized.
Minimal
Tapes are scheduled for inspection if an inspection is
necessary given the tape's current state.
Never
Tapes are not automatically scheduled for inspection.