Engineering and remote access
7.8 OPC UA server
Power supply system SITOP PSU8600
328
Manual, 09.2018, A5E36758446-5-76
7.8.6.19
SubDevices
In folder "SupportedTypes", variables and methods are listed, which are available for the
supported expansion and buffer modules.
SITOP BUF8600 buffer modules with electrolytic capacitors
Relates to: 6EP4297-8HB00-0XY0, 6EP4297-8HB10-0XY0
ActualState
Display name
Data type
Definition
Description
ModuleInternalBufferVoltage
2)
Float
AnalogItemType
Internal buffer voltage
ModuleState
Byte
MultiStateDiscrete-
Type
Operating mode
ModuleStateLed
Object
1)
Sitop_8600_LedType Status of the LED at the buffer
module
ModuleUzkVoltage
2)
Float
AnalogItemType
Internal supply voltage
1)
with variables "Colour" and "State"
2)
Not supported, value = 0