SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
251
2 Parameters
2.2 List of parameters
0 ... 25 %:
The function limit has been reached. A service is recommended.
26 ... 100 %:
The encoder is working in the specified range.
Index:
[0] = Function reserve 1
[1] = Function reserve 2
[2] = Function reserve 3
[3] = Function reserve 4
Dependency:
Refer to: p4650
Note:
Value = 999 means:
- the component specified in p4650 is not connected
- the encoder does not support the display of the functional reserve
Description:
Sets the mode to reset the actual value in XIST_ERW (CO: r4653).
Value:
0:
Inactive
1:
Reset with zero mark
2:
Reset with BICO
3:
Reset with selected zero mark
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency:
Refer to: r4653, r4654, p4655
Note:
If value = 1:
The value in XIST1_ERW is reset when passing every zero mark.
If value = 2:
The value in XIST1_ERW is reset with a 0/1 edge via binector input p4655.
If value = 3:
The value in XIST1_ERW is reset after a 0/1 edge via binector input p4655 when passing the next zero mark.
Description:
Display and connector output for the actual value XIST1_ERW.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency:
Refer to: p4652, r4654, p4655
p4652[0...2]
XIST1_ERW reset mode / XIST1_ERW res mode
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
4750
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 3
0
r4653[0...2]
CO: XIST1_ERW actual value / XIST1_ERW actval
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
4750
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......