2 Parameters
2.2 List of parameters
SINAMICS DCM
422
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets the rate time for the lead/lag element.
Dependency:
Refer to: p50207, p50209, r52156
Description:
Sets the filter time for the lead/lag element.
Dependency:
Refer to: p50207, p50208, r52156
Description:
Displays the effective droop on the speed controller.
Notice:
The effective droop is displayed as absolute factor without any dimensions and it is especially important to note that
it is not a percentage.
Example:
r50217 = 0.05 --> corresponds to an effective droop of 5 %.
Description:
Displays the effective integral time (Tn) on the speed controller.
Description:
Displays the effective P gain (Kp) on the speed controller.
p50208[0...n]
Lead/lag element rate time / Lead/lag t_rate
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
2 [ms]
10000 [ms]
2 [ms]
p50209[0...n]
Lead/lag element filter time / Lead/lag t_filter
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
2 [ms]
10000 [ms]
2 [ms]
r50217
Speed controller droop effective / n_ctr droop eff
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6805
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r50218
Speed controller integral time effective / n_ctr Tn eff
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6805
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [s]
- [s]
- [s]
r50219
CO: Speed controller P-gain effective / n_ctr Kp eff
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6805
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...