2 Parameters
2.2 List of parameters
SINAMICS DCM
460
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets the signal sources for generating the creep setpoint (CO: r52201).
Dependency:
Refer to: r52201
Description:
Setting to enable/disable the impact of the individual creep setpoints when generating signal r53170.12, "Bypass
ramp-function generator".
Value:
0:
Do not bypass
1:
Bypass
Note:
[0]: Enable bypassing of ramp-function generator at creep setpoint 0
...
[7]: Enable bypassing of ramp-function generator at creep setpoint 7
Description:
Sets the signal source for the default setpoint when creep is not selected.
Description:
Sets the signal source for shutting down/resetting the injection of the creep setpoint.
Description:
Sets whether the ON command is triggered by a logic 1 level or a 0/1 edge.
p50441[0...7]
CI: Signal source for creep setpoint / Cr set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
3130
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
p50442[0...7]
Creep setpoint bypass ramp-function generator / Cr set bypass RFG
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
3130
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p50443[0...n]
CI: Creep signal source for default setpoint / Cr def set sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
CDS, p0170
Func. diagram:
3130
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52207[0]
p50444[0...n]
BI: Creep signal source for shutdown / Cr shutdn sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
CDS, p0170
Func. diagram:
3130
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50445
Creep setpoint level/edge / Cr set lev/ed
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
3130
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......