2 Parameters
2.2 List of parameters
SINAMICS DCM
634
List Manual (LH8), 02/2015, 6RX1800-0ED76
Note:
Re bit 00:
1 signal: The relay output for the line contactor is activated via binector input p51619.
0 signal: The relay output for the line contactor is de-activated via binector input p51619.
Description:
Display and connector output for the status in the event of an E stop (emergency stop).
Description:
Displays the state of the motor interface.
Dependency:
Refer to: p50486, p50487, p50488, p50489
Refer to: F60025, F60026, F60027, F60028
Description:
Displays the state of temperature monitoring on the motor interface.
Dependency:
Refer to: p50490, p50491, p50492
Refer to: F60029, A60032
r53100.0...1
CO/BO: E stop status / E stop stat
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2070, 2580
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
No E stop
Yes
No
2070,
2580
01
E stop active
Yes
No
2070
r53120.0...3
CO/BO: Motor control checks / Mot mon state
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
8035
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Brush length too short
Yes (fault)
No
-
01
Poor bearing condition
Yes (fault)
No
-
02
Motor fan fault
Yes (fault)
No
-
03
Motor temperature too high
Yes (fault)
No
-
r53130.0...1
CO/BO: Motor interface temperature monitoring state / Mot temp_mon
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
8030
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Motor temperature alarm
Yes
No
-
01
Motor temperature fault
Yes
No
-
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......