SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
379
2 Parameters
2.2 List of parameters
o12.4 Offset calibr. of curr. act. val. sensing being performed
o12.5 Read out data from the power unit
o12.6 Wait for second processor (TMS320) to go into normal operation
Description:
Displays the motor temperature.
The temperature sensor is connected via terminal X177.53/54/55 of the CUD.
Dependency:
The temperature value is only displayed when using one of the following temperature sensors:
- KTY84 (p50490 = 1): measuring range = -40 °C to +300 °C
- PT100 (p50490 = 6): measuring range = -200 °C to +300 °C
- NTC thermistor K227 (p50490 = 7): measuring range = +85 °C to +200 °C
- PT1000 (p50490 = 8): measuring range = -200 °C to +300 °C
Refer to: p50490, r52051
Note:
If p50490 = 0, 2 to 5, a value of 0 is displayed.
Description:
Displays the temperature of the various temperature sensors for device and modules.
Index:
[0] = Temperature sensor 1
[1] = Temperature sensor 2
[2] = Temperature sensor 3
[3] = Gating module temperature
[4] = CUD Control Unit temperature
Note:
Temperature sensors which are not in use return a high negative value (approx. -200 °C).
Description:
Displays the values calculated for the temperature rise of the motors and the thyristors.
Index:
[0] = Motor temperature rise
[1] = Thyristor temperature rise
Dependency:
Refer to: p50075, r52310
r50012
Motor temperature / Mot temp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
8030
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r50013[0...4]
Temperature sensor/Module / Temp sensor/Mod
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
8048
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r50014[0...1]
Temperature rises calculated / Temp rise calc
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
8038, 8042
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......