2 Parameters
2.2 List of parameters
SINAMICS DCM
176
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets the faults/alarms for which a trigger signal should be generated in r2129.0...15.
Dependency:
If the fault/alarm set in p2128[0...15] occurs, then the particular binector output r2129.0...15 is set.
Refer to: r2129
Description:
Sets the faults/alarms for which a trigger signal should be generated in r2129.0...15.
Dependency:
If the fault/alarm set in p2128[0...15] occurs, then the particular binector output r2129.0...15 is set.
Refer to: r2129
Description:
Display and BICO output for the trigger signals of the faults/alarms set in p2128[0...15].
Dependency:
If the fault/alarm set in p2128[0...15] occurs, then the particular binector output r2129.0...15 is set.
Refer to: p2128
Note:
CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
p2128[0...15]
Faults/alarms trigger selection / F/A trigger sel
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S, DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
8070
P-Group:
Messages
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
p2128[0...15]
Faults/alarms trigger selection / F/A trigger sel
TM150, TM15DI_DO,
TM31
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
8050, 8070
P-Group:
Messages
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
r2129.0...15
CO/BO: Faults/alarms trigger signal / F/A trigger signal
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
8070
P-Group:
Messages
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Trigger signal p2128[0]
ON
OFF
-
01
Trigger signal p2128[1]
ON
OFF
-
02
Trigger signal p2128[2]
ON
OFF
-
03
Trigger signal p2128[3]
ON
OFF
-
04
Trigger signal p2128[4]
ON
OFF
-
05
Trigger signal p2128[5]
ON
OFF
-
06
Trigger signal p2128[6]
ON
OFF
-
07
Trigger signal p2128[7]
ON
OFF
-
08
Trigger signal p2128[8]
ON
OFF
-
09
Trigger signal p2128[9]
ON
OFF
-
10
Trigger signal p2128[10]
ON
OFF
-
11
Trigger signal p2128[11]
ON
OFF
-
12
Trigger signal p2128[12]
ON
OFF
-
13
Trigger signal p2128[13]
ON
OFF
-
14
Trigger signal p2128[14]
ON
OFF
-
15
Trigger signal p2128[15]
ON
OFF
-
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......