SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
243
2 Parameters
2.2 List of parameters
Dependency:
Refer to: p4102, p4103, r4105, p4118
Description:
Display and binector output for the status for the Terminal Module 31 (TM31).
Dependency:
Refer to: p4102
Description:
Displays the temperature actual value for the Terminal Module 150 (TM150)
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
[4] = Temperature channel 4
[5] = Temperature channel 5
[6] = Temperature channel 6
[7] = Temperature channel 7
[8] = Temperature channel 8
[9] = Temperature channel 9
[10] = Temperature channel 10
[11] = Temperature channel 11
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Channel 0 alarm present
Yes
No
9626
01
Channel 0 fault present
Yes
No
9626
02
Channel 1 alarm present
Yes
No
9626
03
Channel 1 fault present
Yes
No
9626
04
Channel 2 alarm present
Yes
No
9626
05
Channel 2 fault present
Yes
No
9626
06
Channel 3 alarm present
Yes
No
9626
07
Channel 3 fault present
Yes
No
9626
08
Channel 4 alarm present
Yes
No
9626
09
Channel 4 fault present
Yes
No
9626
10
Channel 5 alarm present
Yes
No
9626
11
Channel 5 fault present
Yes
No
9626
12
Channel 6 alarm present
Yes
No
9627
13
Channel 6 fault present
Yes
No
9627
14
Channel 7 alarm present
Yes
No
9627
15
Channel 7 fault present
Yes
No
9627
16
Channel 8 alarm present
Yes
No
9627
17
Channel 8 fault present
Yes
No
9627
18
Channel 9 alarm present
Yes
No
9627
19
Channel 9 fault present
Yes
No
9627
20
Channel 10 alarm present
Yes
No
9627
21
Channel 10 fault present
Yes
No
9627
22
Channel 11 alarm present
Yes
No
9627
23
Channel 11 fault present
Yes
No
9627
r4104.0...1
BO: TM31 temperature evaluation status / TM31 temp status
TM31
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
9549, 9576
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Alarm is present
Yes
No
-
01
Fault is present
Yes
No
-
r4105[0...11]
CO: TM150 temperature actual value / TM150 temp_act val
TM150
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
9626, 9627
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......