SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
295
2 Parameters
2.2 List of parameters
Description:
Setting to backup/import/delete NVRAM data.
NVRAM data are non-volatile data in the device (e.g. fault buffer).
For NVRAM data actions, the following data are excluded:
- Crash diagnostics
- CU operating hours counter
- CU temperature
- Safety logbook
Value:
0:
Inactive
1:
NVRAM data backup to memory card
2:
Import NVRAM data from the memory card
3:
Delete NVRAM data in the device
10:
Error when clearing
11:
Error when backing up, memory card not available
12:
Error when backing up, insufficient memory space
13:
Error when backing up
14:
Error when importing, memory card not available
15:
Error when importing, checksum error
16:
Error when importing, no NVRAM data available
17:
Error when importing
Notice:
Re value = 2, 3:
These actions are only possible when pulses are inhibited.
Note:
After the action has been successfully completed, the parameter is automatically set to zero.
The actions importing and deleting NVRAM data immediately initiate a warm restart.
If the procedure was not successfully completed, then an appropriate fault value is displayed (p7775 >= 10).
Description:
Sets the component number of the DRIVE-CLiQ component whose parameters are to be accessed.
Dependency:
Refer to: p7821, p7822, r7823
Description:
Sets the parameter number to access a parameter of a DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7822, r7823
p7775
NVRAM data backup/import/delete / NVRAM backup
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
C1, U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 17
0
p7820
DRIVE-CLiQ component component number / DQ compo_no
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
p7821
DRIVE-CLiQ component parameter number / DQ para_no
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......