SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
537
2 Parameters
2.2 List of parameters
Description:
Sets the setpoint for the positive start pulse on the speed controller.
Recommendation:
The value can also be used as an integrator setting value for the speed controller.
Description:
Sets the factor for the start pulse when the setpoint is negative.
Description:
Sets the setpoint for the negative start pulse on the speed controller.
Description:
Sets the signal source for the setpoint of the positive start pulse on the speed controller.
Description:
Sets the signal source for the setpoint of the negative start pulse on the speed controller.
p51651[0...n]
Speed controller start pulse positive setpoint / Start pul pos set
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6800
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-100.00 [%]
100.00 [%]
0.00 [%]
p51652[0...n]
Speed controller start pulse negative factor / Start pul neg fact
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6800
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.00 [%]
200.00 [%]
50.00 [%]
p51653[0...n]
Speed controller start pulse negative setpoint / Start pul neg set
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6800
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
-100.00 [%]
100.00 [%]
0.00 [%]
p51655
CI: Speed controller start pulse positive signal source / Start p pos sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
6800
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52451[0]
p51656
CI: Speed controller start pulse negative signal source / Start p neg sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
6800
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52452[0]
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......