2 Parameters
2.2 List of parameters
SINAMICS DCM
434
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets the smoothing time constant for the EMF controller's setpoint.
Dependency:
Refer to: p50282
Note:
This smoothing enables the EMF controller pre-control to be decoupled from the EMF controller.
Description:
Sets the smoothing time constant for the EMF controller's actual value.
Dependency:
Refer to: p50281
Note:
This smoothing enables the EMF controller pre-control to be decoupled from the EMF controller.
Description:
Sets the smoothing time constant for the actual value for EMF controller pre-control.
Dependency:
Refer to: p50280
Note:
This smoothing enables the EMF controller pre-control to be decoupled from the EMF controller.
Description:
Sets activation/de-activation of the proportional component on the EMF controller.
Value:
0:
Deactivated
1:
Activated
Dependency:
Refer to: p50275, p50276
Note:
If value = 0:
The proportional component of the EMF controller is kept constantly at zero (i.e. the EMF controller functions solely
as an integral controller).
p50281[0...n]
EMF controller setpoint smoothing time constant / EMF ctr set T
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50282[0...n]
EMF controller actual value smoothing time constant / EMF ctr act T
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50283[0...n]
EMF controller pre-control actual value smoothing time constant / EMF prec act T
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50284[0...n]
EMF controller proportional component activation / EMF ctr P comp act
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
1
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......