2 Parameters
2.2 List of parameters
SINAMICS DCM
566
List Manual (LH8), 02/2015, 6RX1800-0ED76
Scaling:
0 % corresponds to 0 °C
100 % corresponds to 100 °C
Dependency:
The parameter is only valid for the following temperature sensors with a continuous characteristic:
- KTY84 (p50490 = 1)
- PT100 (p50490 = 6)
- NTC thermistor K227 (p50490 = 7)
- PT1000 (p50490 = 8)
Refer to: p50490
Note:
If p50490 = 0, 2 to 5, a value of 0 is displayed.
Description:
Display and connector output for the armature firing angle after limiting by the auto-reversing stage.
Description:
Display and connector output for the armature firing angle before limiting by the auto-reversing stage.
Description:
Display and connector output for the output to the armature gating module (pre-control value + armature current
controller output).
Description:
Displays the armature current flow duration/time ratio between 2 consecutive firing pulses.
r52100
CO: Armature firing angle after limiting / Fir ang aft lim
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6860
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52101
CO: Armature firing angle before limiting / Fir ang bef lim
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6860, 6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52102
CO: Cl-loop arm curr ctrl prectr value + arm curr controller output / Ia ctr prec+outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6855
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52103
CO: Armature current flow duration / Arm I_flow dur
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6850
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......