SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
289
2 Parameters
2.2 List of parameters
Description:
Displays the GUID of all the OA applications installed on the memory card/device memory.
r4992[0...15]: GUID of OA application 1
r4992[16]: Major information of OA application 1
r4992[17]: Minor information of OA application 1
r4992[18...33]: GUID of OA application 2
r4992[34]: Major information of OA application 2
r4992[35]: Minor information of OA application 2, ...
Dependency:
Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4993, r4994
Notice:
If there is no OA application, then it is not possible to access an index.
Description:
Displays the activation status of the OA applications installed on the memory card/device memory.
r4993[0]: Activates OA application 1
r4993[1]: Activates OA application 2, ...
Value:
0:
OA application inactive
1:
OA application active
Dependency:
Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4994
Notice:
If there is no OA application, then it is not possible to access an index.
Description:
Displays the properties of all the OA applications installed on the memory card/device memory.
r4994[0]: Version of OA application 1
r4994[1]: Version of OA application 2, ...
Dependency:
Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993
Notice:
If there is no OA application, then it is not possible to access an index.
Note:
The parameter is only for internal Siemens diagnostics.
r4992[0...n]
OA GUID ES / OA GUID ES
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
r4987
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4993[0...n]
OA activation status / OA act stat
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Integer16
Dyn. index:
r4985
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
-
r4994[0...n]
OA properties / OA property
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dyn. index:
r4985
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Properties diagnostics bit 0
Yes
No
-
01
Properties diagnostics bit 1
Yes
No
-
02
Properties diagnostics bit 2
Yes
No
-
03
OEM
No
Yes
-
04
Properties diagnostics bit 4
Yes
No
-
05
Properties diagnostics bit 5
Yes
No
-
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......