SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
571
2 Parameters
2.2 List of parameters
Description:
Display and connector output for the active power for a pure ohmic load (= r52126 * r52127).
The value is averaged over six firing cycles.
Note:
This quantity is used for heating applications (rms value current control or rms value power control).
Description:
Display and connector output for the current controller setpoint after reduced gearbox stressing.
Description:
Display and connector output for the rms value of the internal armature current actual value.
The value is averaged over 6 firing cycles, and referred to the rated device current (r50072[1]).
Description:
Display and connector output for the rms value of the armature voltage.
The value is averaged over six firing cycles.
100 % corresponds to (3 * sqrt(2)) / Pi * p50078[0] = 1.35 * p50078[0] (= U_di0_rated)
Description:
Displays the linearized firing angle.
Dependency:
Refer to: p50600
r52124
CO: Active power for a pure ohmic load / P_act ohm load
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6902
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52125
CO: Curr limitation arm curr setpoint aft reduced gearbox stressing / Ia set aft gear
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6845
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52126
CO: Armature current actual value rms value / Ia_act rms
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6851
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52127
CO: Armature voltage rms value / Ua_act rms
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6902
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52128
CO: Firing angle linearized / Firing angle lin
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6858
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......