Description:
Sets and displays the wire resistance for Terminal Module 150 (TM150).
The value is used for the automatic conductor calibration.
The value is automatically set by starting the wire resistance measurement (p4109[0...11]) of the corresponding
channel.
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
[4] = Temperature channel 4
[5] = Temperature channel 5
[6] = Temperature channel 6
[7] = Temperature channel 7
[8] = Temperature channel 8
[9] = Temperature channel 9
[10] = Temperature channel 10
[11] = Temperature channel 11
Dependency:
Refer to: p4109
Notice:
Wire resistance measurement is only possible for 1x2 or 2x2 wire evaluation (p4108[0...5] = 0, 1).
Note:
Automatic conductor calibration is deactivated using p4110[0...11] = 0.
Description:
Assigns the temperature channels to groups for the Terminal Module 150 (TM150)
For each group, the following calculated values are provided from the temperature actual values (r4105[0...11]):
- Maximum value (r4112[0...2])
- Minimum value (r4113[0...2])
- average value (r4114[0...2])
Index:
[0] = Group 0
[1] = Group 1
[2] = Group 2
Dependency:
Refer to: r4105, r4112, r4113, r4114
p4110[0...11]
TM150 wire resistance value / TM150 R_wire value
TM150
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
9626, 9627
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ohm]
3000.00 [ohm]
0.00 [ohm]
p4111[0...2]
TM150 group channel assignment / TM150 grp channel
TM150
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
9625
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Temperature channel 0
Yes
No
-
01
Temperature channel 1
Yes
No
-
02
Temperature channel 2
Yes
No
-
03
Temperature channel 3
Yes
No
-
04
Temperature channel 4
Yes
No
-
05
Temperature channel 5
Yes
No
-
06
Temperature channel 6
Yes
No
-
07
Temperature channel 7
Yes
No
-
08
Temperature channel 8
Yes
No
-
09
Temperature channel 9
Yes
No
-
10
Temperature channel 10
Yes
No
-
11
Temperature channel 11
Yes
No
-
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......