SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
541
2 Parameters
2.2 List of parameters
Description:
Sets the save interval,
during which the signals recorded internally are saved to the following recording file:
\USER\SINAMICS\DATA\LOG\Track.csv
Dependency:
Refer to: p51700, p51701, p51702, p51703, p51705, p51706
Notice:
The value is set in minutes.
Description:
Setting to start and stop the recorder function.
Value = 1:
Recording is started and stopped after reaching of the number of entries set in p51706. p51705 is set to 0.
Value = 2:
Recording is started: After reaching of the number of entries set in p51706, the file is overwritten from the beginning.
Recording runs until it is stopped by setting of p51705 = 0.
Value:
0:
Stop
1:
Start
2:
Start with overwrite
Dependency:
Refer to: p51700, p51701, p51702, p51703, p51704, p51706
Notice:
Starting the recorder function overwrites any existing recording file.
Description:
Sets the number of entries in the recorder function's recording file.
Dependent upon the start command (p51705 = 1 or 2), recording is stopped after this number of entries has been
reached or the recording file is overwritten from the beginning.
Dependency:
Refer to: p51700, p51701, p51702, p51703, p51704, p51705
Description:
All fault message responses are not immediately initiated, but only after a parameterizable delay time.
p51704
Recorder function save interval / Rec fct t_save
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
8050
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 60
1
p51705
Start/stop recorder function / Rec fct StartStop
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
8050
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
0
p51706
Recorder function number of entries / Rec fct num ent
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
8050
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
10 100000
3600
p51780
Fault message response delay time / F delay_time
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2651
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
60.000 [s]
0.000 [s]
Содержание SINAMICS DCM
Страница 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Страница 2: ......
Страница 856: ...3 Function diagrams 3 23 Basic Operator Panel 20 BOP20 SINAMICS DCM 856 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1178: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS DCM 1178 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Страница 1203: ......